Sampling and Containers

How much sample is required for TCLP analysis?
The required amount of soil for TCLP analysis is 110 grams in order to be complaint with TCLP methodology.   Bureau Veritas Laboratories can do a modifi...
Tue, 7 May, 2019 at 12:46 PM
What containers are required for O.Reg 153 Petroleum Hydrocarbons (PHCs)?
The sampling requirements for Ontario Regulation 153 (O.Reg 153) PHCs are as follows: Soil:                            AnalysisNumber of  ContainersCon...
Wed, 16 Jan, 2019 at 8:35 AM
What containers are required for O.Reg 153 Volatile Organic Compounds (VOCs)?
The sampling requirements for Ontario Regulation 153 (O.Reg 153) VOCs are as follows: AnalysisNumber of ContainersContainer SizeContainer TypePreservativ...
Wed, 16 Jan, 2019 at 10:03 AM
What containers are required for O.Reg 153 Polycyclic Aromatic Hydrocarbons (PAHs)?
The sampling container requirements for Ontario Regulation 153 (O.Reg 153) PAHs are as follows: Water: AnalysisNumber of ContainersContainer SizeContain...
Thu, 17 Jan, 2019 at 11:03 AM
What containers are required for O.Reg 153 Polychlorinated Biphenyls (PCBs)
The sampling container requirements for Ontario Regulation 153 (O.Reg 153) for PCBs are as follows: Water AnalysisNumber of ContainersContainer SizeCont...
Wed, 16 Jan, 2019 at 11:39 AM
What containers are required for O.Reg 153 Metals and Inorganics?
The sampling container requirements for Ontario Regulation 153 (O. Reg 153) are as follows: Water: AnalysisNumber of ContainersContainer SizeContaine...
Wed, 16 Jan, 2019 at 12:28 PM
Free Cyanide - Sampling Procedure
The attached details outline the procedure for sampling for free cyanide and field testing for possible interferences. If you have any questions regardi...
Wed, 6 Jul, 2022 at 10:42 AM
Can I use methanol vials from another or previous project?
Yes. If you find you have methanol vials remaining from a previous order or project, they can be used for another sample submission. They only cauti...
Wed, 16 Jan, 2019 at 2:00 PM
Sampling for Dissolved Oxygen - Western Provinces
Dissolved Oxygen (DO) in water can help to determine the relative oxygen saturation in an aquatic environment. In order to capture the amount of dissolved o...
Thu, 29 Nov, 2018 at 10:49 AM
PFAS - Containers and Hold Time
Waters - Samples should be collected in wide mouth (HDPE) bottles fitted with an unlined (no Teflon) polypropylene screw cap.  - 125mL HDPE. Please su...
Tue, 7 May, 2019 at 9:44 AM